Your Cart: 0 Items
Promotional Code?
Subtotal
$0.00 USD
Cart items expire in 1 hour, not reserved.
Skip to product information
1 of 7

5ml Pipette Tips

In Stock: 15

Regular price $32.99
Regular price Sale price $32.99
Sale Contact Us
Product Information Product code : PTS5000-EA
● Autoclavable. Non-Pyrogenic, DNase/RNase free to eliminate the risks of pollution.
● Provide high accuracy with soft conical design and tight sealing.
● Highly accurate tips with low retention technology minimize liquid residue.
● Perfect airtight seal ensures no leak and maximizes the recovery of samples and reagents.
● Rack pack allows direct loading into pipettor without hand touch creating higher sterility and efficiency.
● Longer connector part creates high compatibility to be used with most popular pipettors like Gilson™, Four E's™, Eppendorf™, Biohit™, Thermo™, Labsystems™, and other known brands
● Easy tip loading and ejection to avoid Repetitive Strain Injuries (RSI).
● Precise lines for easy access and storage.

Does Four E‘s USA offer Free Shipping in the USA?

We offer FREE GROUND SHIPPING on orders within the contiguous 48 States in the USA (excluding Alaska and Hawaii). No promo code is needed for free shipping! We cannot ship to PO Boxes, so please provide a full, physical street address in your Shipping Address.

What are the Delivery Time Frames?

Unless otherwise noted, orders are processed every business day and are normally delivered within 3-8 business days. Large volumes of items or heavy items may require delivery by freight truck. If your purchase requires this shipping method, we will contact you in advance by email with additional information about freight truck deliveries.

I ordered more than one item. Will they all be delivered at the same time?

We try to make sure your Items ordered together reach you at the same time. Sometimes your items are not always shipped on the same day or in the same carton since different shipping options are used, depending on the product. Once an item has been shipped, you will receive a shipment notification email.

Can I change the delivery address of my package after it has been shipped out?

Unfortunately, we cannot change the shipment once the product is on the way to the delivery address of your order. For more information, please get in touch with our Support Team at support@4Es-USA.com at any time.
Coming soon


payment icons

Choose distributor

Four E’s Just Made Their Best Pipette, Better

Four E’s is a leading manufacturer of branded and privatelabel pipettes. Years of designing and manufacturing led to the launch of thePer4mance line of single channel adjustable pipettes. Per4mance pipettes have asleek design to match the upgraded internal materials and design. All Per4mancepipettes are factory calibrated and supplied with the ISO 8655 calibration testsheet.    

Ergonomic
Design


Large Volume
Display


Designed for Right
and Left Handers


Autoclavable
Lower Section

  • Specifications
  • Features
  • Downloads
Model Volume Range Increment Maximum permissible systematic error Maximum permissible random error Color
P4-SA0301001 0.1-2.0μl 0.002ul 2.50% 2.0% Black
P4-SA0301002 0.5-10μl 0.01ul 1.00% 0.80% Grey
P4-SA0301003 2-20μl 0.02ul 0.90% 0.40% Red
P4-SA0301004 5-50μl 0.05ul 0.60% 0.30% Blue
P4-SA0301005 10-100μl 0.1ul 0.80% 0.15% Dark Grey
P4-SA0301006 20-200μl 0.2ul 0.60% 0.15% White
P4-SA0301007 100-1000μl 1ul 0.60% 0.20% Light Blue
P4-SA0301008 1000-5000μ 5ul 0.60% 0.15% Pink
P4-SA0301009 1-10ml 10ul 0.60% 0.20% Beige

Features

  • Lower plunger pressure avoids repetitive strain injuries

  • Different color tops indicate pipette volume range of 0.1ul-10ml

  • 4-position window display can be viewed when used by left or right handers

  • Upgraded internal design and material changes to enhance performance

  • Autoclavable lower section for proper disinfection

  • High-elastic tip cone provides a good seal and easy removal of tips from many different manufacturers

  • Calibrated in accordance with ISO8655 and each pipette is supplied with an individual test certificate

Precipette Data Sheet

Tip Compatibility

User Manual

Pipette Tips for All Pipette Manufacturers

Pipetting Just Got Easier

Four E’s Per4mance pipette is designed to be extremelyergonomic in shape and motion. The low force required to pipette or changepipette tips mitigates repetitive stress injuries that can occur withlaboratory processes.  Combined with theperformance of Four E’s liquid handling devices this line of pipettes is greatfor pipetting aliquots into tubes, plates, or flasks. Four E’s offers a widerange of volume capabilities and pipettes are easily identified through theircap color.

Ensuring a Sterile Sample is the Least We Could Do

Ensuring a Sterile Sample is the Least We Could DoThe Per4mance line of pipettes was designed tobe effective and affordable. Maintaining a desirable price point to allow forsterilization of the lower section was a key element in engineering theseprecision liquid handling devices. The lower section can easily be removed andthe liquid handling components can be autoclaved to eliminate contamination. Eachpipette is supplied in a rigid box with calibration tools, pipette grease,calibration test sheet, sample pipette tip, and a user manual.

4E's vs. Other Brands

4E’S
Brand X
Brand Y

ISO 8655 Calibrated

Calibration Sheet

Ambidextrous Design

Competitive Price

Lower Portion Autoclavable

Easily Disassembled

Exception Tip Compatibility

Low Plunger Force to Reduce Injury

Easy Calibration

Reviews

Frequently Asked Questions

Everything you need to know about product and billing. Can’t find the answer you are looking for? Please write your question to us at info@4Es-USA.com

What Brand Tips Do Your Pipettes Work With?

Our pipettes are designed to work with most supplier’s pipette tips due to the innovative tip design. We also provide pipette tips specifically for our pipettes. Please refer to the tip compatibility chart to make sure the tips are compatible with Four E’s USA pipettes.

Do you sell Pipette tips?

Yes, we do. We sell pipette tips in bulk, racked, sterile, nonsterile, low retention, filtered and non-filtered.

Is the Pipette Autoclavable?

The Precipette features an autoclavable lower portion. This allows for sterilizing of the liquid handling mechanism. Please refer to our manual or videos for more information on disassembly or sterilization.

What is included with the pipette?

All pipettes are shipped individually in sturdy boxes. In the box you will find a comprehensive multi-language manual, an individual calibration certificate to ISO 8655 standards, a calibration tool, pipette grease, sample pipette tip, replacement calibration stickers, and an adjustable volume pipette.

Can I order the Pipettes in Bulk?

Yes, Four E’s is one of the largest designers and manufacturers of pipettes and we offer our pipettes in bulk, private label with customizations available.

Who do I contact if I have an issue calibrating the pipette?

Four E’s USA, headquartered in West Windsor, NJ, has customer service representatives standing by to help with calibration, parts, or product questions.

What is the warranty on the pipette?

Yes, there is a full 12-month warranty on the pipette.

Is there a rack to organize the pipettes?

Four E’s offers universal pipette racks that are compatible with all Four E’s pipette models and most competitor pipettes.

How do I disassemble the pipette?

The pipette can be disassembled, cleaned, and autoclaved without the use of any tools. Refer to the product manual for in-depth disassembly instructions. To disassemble, the ejector sleeve is pressed down, and the lower portion of the pipette is pulled down and rotated. This will separate the major components. The pipette tip then can be unscrewed from the unit to expose the pipette internal components for cleaning and sterilizing.

What is the procedure for calibrating the pipette?

Please refer to the product manual for detailed calibration instructions. To calibrate the pipette the calibration tool is inserted in the calibration port. The volume setting ring is turned to adjust the dispensing volume as required to meet the calibration requirements. The displayed volume should not change when rotating the volume setting ring during calibration.